在线投稿 证书查询
Experimental study on the collection efficiency of gas collection hoods in the plastic products industry under the effect of flue gas temperature
作者:Wang Shouyang
中国分类号:TQ320.8
文献标识码:B
文章标识码:1009-797X(2026)05-0033-05
关键词:gas collection hood; flue gas temperature; collection efficiency; regression equation

摘要

The gas collection hood is a crucial component of the waste gas treatment system, and its collection efficiency directly impacts the treatment effectiveness. To clarify the relationship between flue gas temperature and the collection efficiency of the gas collection hood, this study took seven plastic product enterprises in Cang County as the research subjects. The point source correction method was employed to deduce the unorganized emission source strength, and the collection efficiency at different temperatures was analyzed. The results showed that within the temperature range of 120~210 ℃, the collection efficiency decreased from 95% to 68%, exhibiting a strong negative correlation (r=-0.977). The regression equation is collection efficiency = -0.00341 × temperature + 1.366. The study suggests that enterprises should pay attention to the impact of flue gas temperature and optimize the design of the gas collection hood.